CRYOGENIC FLOW CONTROLS (CFC VIETNAM)
[A] : 9th Floor, C.T Building, 56 Yen The Str., Ward 2, Tan Binh Dist., HCMC, Vietnam
[P] : (+84) 28 5449 2068 - [F] : (+84) 28 5449 2069
[E] : hung.nguyen@cfc-vietnam.vn
[W] : www.cfc-vietnam.vn
|
❶ Pump ID Meaning
MRP 40 / 40 or 55 (model) (piston Ø in mm)(piston stroke in mm) |
|
Application |
Cylinder and buffer tank filling |
Liquid Pumped |
LOX, LIN, LAr, LCO2, LN20,LNG |
Drive Type |
Grease lubricated crank drive |
Design pressure |
420 bar / 6100 PSI |
❷ Test Procedure
Each pump manufactured by CRYOSTAR is mechanically and cryogenically tested prior to shipment in our state-of-the-art testing facility to ensure that performance meets customer specification. The precision of measuring devices provides essential results: differential head, flow rate, seal gas consumption, pump efficiency, NPSH, noise and vibration levels - all documented and submitted to the customer.
❸ Quality
Designed in compliance with guidelines like IGC 11/82 norm
❹ Features
1 Small mass of the suction chamber (faster/better cool down)
2 Large suction chamber volume
3 Direct degassing at the highest point of the cold end (further improved by a 45° slope of the discharge line)
4 Improved vacuum volume
5 Suction valve optimized to reduce pressure drops
6 Optimized design and position of the vacuum connection
7 Waved line on the cylinder to avoid stresses resulting from cold contraction (extends cylinder life)
8 Increased number of piston rings for higher volumetric efficiency
9 Optimized sealing and guidance of the monel piston
10 PT100 probe for seal leak detection
11 Open intermediate piece no need for purge
12 Following features offer an extended lifetime :
13 Oil splash lubricated crank drive with autonomous lubricating system independent of rotating direction
PT100 probe for anti-cavitation and leak detection included in standard scope of supply.
❺ Options
MRP Pump ID Meaning
MRP 40 / 40 or 55 (model) (piston Ø in mm)(piston stroke in mm) |
|
Application |
Cylinder and buffer tank filling |
Liquid Pumped |
LOX, LIN, LAr, LCO2, LN20,LNG |
Drive Type |
Grease lubricated crank drive |
Design pressure |
420 bar / 6100 PSI |