CRYOGENIC FLOW CONTROLS (CFC VIETNAM)
[A] : 9th Floor, C.T Building, 56 Yen The Str., Ward 2, Tan Binh Dist., HCMC, Vietnam
[P] : (+84) 28 5449 2068 - [F] : (+84) 28 5449 2069
[E] : hung.nguyen@cfc-vietnam.vn
[W] : www.cfc-vietnam.vn
|
APPLICATIONS |
|||||
INDUSTRY |
SERVICE |
PARAMETER |
RANGE |
BACKGROUND |
TELEDYNE MODEL |
Flue Gas Desulferization (FGD) |
Inlet to fluidized bed / absorber |
Percent SO2 |
0-1% |
Flue gas |
Series 6000 UV |
Outlet from fluidized bed / absorber |
PPM SO2 |
0-250, 0-500 ppm |
|||
ON-LINE / CONTINUOUS |
|||||
Excess O2 |
Stack gas analysis |
Percent O2 |
0-5% |
Flue gas |
9060Z (ZrO2) |
Combustion efficiency |
PPM CO |
0-1000 ppm |
|||
Percent combustibles |
0-5% CH4 eq |
9700 for heavy, solid fuels |
|||
|
|||||
Pollution abatement |
Continuous emission monitor |
PPM SO2 |
0-250 to 0-5000 ppm |
Flue gas |
|
CEM / Stack gas |
PPM NOx |
0-10 to 0-5000 ppm |
|||
|
|||||
H2 purity |
Percent H2 |
80-100% |
Air |
||
CO2 purge of H2 from turbine |
Percent CO2 |
0-100% |
H2 |
||
Air purge of CO2 from turbine |
Percent Air |
0-100% |
CO2 |
||
|
|||||
Boiler tube control |
Oil in boiler return steam condensate |
PPM oil |
0-10 ppm |
Condensate |
6600 (UV) |
|
|||||
Cooling water |
Hydrocarbons in cooling H2O |
PPM hydrocarbons |
0-10 ppm |
Water |
4020 + 1100A stripper |
|
|||||
INDUSTRY |
SERVICE |
PARAMETER |
RANGE |
BACKGROUND |
TELEDYNE MODEL |
PORTABLE ANALYZERS |
|||||
Excess O2 / Boiler |
Stack gas analysis |
Percent O2 |
0-5% |
Flue gas |
|
Percent O2; PPM CO Comb |
See data sheet |
||||
|
|||||
Pollution abatement |
Stack gas analysis |
Percent O2; |
See data sheet |
Flue gas |
|
|
|||||
H2 purity / turbine maintenance |
Percent H2, CO2, Air |
See data sheet |
Air, H2, CO2 |
||
SF6 Filling |
Electrical apparatus / switchbox |
PPM O2 |
0-10 ppm |
SFG |
|
|
|||||
Bechtel Spec |
Battery room analysis |
Percent H2 |
0-100% LEL |
Air |
1223 commercial grade |
|
|||||
BNFL (UK) |
Nuclear fuels conversion of uranium ores to UF6 |
Percent F2 |
0-50% |
UF6, HF, O2, CF4 |
Series 6000 UV (commercial) |
|
|||||
KEPCO - Korea |
Gaseous waste treatement |
Percent O2 |
0-5, 0-10% |
N2 |
Series 3000(commercial) |
|
|||||
KEPCO - Korea |
Deuterium (D2) in air |
Percent D2 |
0-5% |
Air |
Series 2000(commercial) |
|
|||||
INDUSTRY |
SERVICE |
PARAMETER |
RANGE |
BACKGROUND |
TELEDYNE MODEL |
Vacuum Drag System |
Recombiner (after condensor) |
Percent H2 |
0-5% H2 |
O2 / N2 |
Series 2000(commercial) |
Feed to off gas compressors |
Percent O2 |
0-5% O2 |
N2 / H2 |
Series 3000(commercial) |
|
|
|||||
Desalination plant |
Seawater electrochlorination unit efficiency performance |
PPM NaOCL (hypochlorite ion) |
0-1500 ppm |
Seawater |
Series 6000 (UV) |