CRYOGENIC FLOW CONTROLS (CFC VIETNAM)
[A] : 9th Floor, C.T Building, 56 Yen The Str., Ward 2, Tan Binh Dist., HCMC, Vietnam
[P] : (+84) 28 5449 2068 - [F] : (+84) 28 5449 2069
[E] : hung.nguyen@cfc-vietnam.vn
[W] : www.cfc-vietnam.vn
|
APPLICATIONS |
||||||
INDUSTRY |
SERVICE |
PARAMETER |
RANGE |
BACKGROUND |
TELEDYNE MODEL |
|
Continuous Catalytic Reformer - CCR: See application note in Petrochemical for Aromatic Plant |
||||||
Fluid Catalytic Cracker Unit - FCCU - 1st & 2nd Stage Regenerator Cyclones |
||||||
|
Catalyst regeneration |
Percent O2 |
0-1% |
Flue gas |
Series 9000 extractive |
|
Percent CO |
0-1%, 0-10% |
7500Z NDIR |
||||
Percent O2 |
0-1, 0-5, 0-25% |
320P plus sample system |
||||
Flue gas / stack incinerator |
Percent O2 & SO2 |
0-5% O2 & 0-1% |
||||
Desulfide separator vent gas |
Percent O2 |
0-25% |
Process gas |
3020MParamagnetic |
||
|
||||||
Hydrocracker Unit |
||||||
|
Recycled gas compressor suction |
Percent H2 |
50-100% |
Hydrocarbons |
||
Make-up gas |
||||||
Total gas downstream confluence point |
||||||
|
||||||
Crude & Vacuum Distillation Units - CDU & VDU |
||||||
|
Color analysis / Diesel product |
ASTM / APHA / Saybolt |
Product dependent |
Fuel oil |
6000 UV |
|
2 Naphtha pumparound to Atm crude tower |
Light naphtha |
6000 UV |
||||
|
||||||
CDU / VDU Heaters |
||||||
|
Stack gas / CEM Appl |
PPM NOx / SOx |
0-500 ppm |
Stack gas |
||
|
||||||
Cooling Tower Water |
||||||
|
Hydrocarbon breakthrough |
PPM hydrocarbons |
0-10 ppm |
Water |
4020 & 1100A stripper |
|
|
||||||
INDUSTRY |
SERVICE |
PARAMETER |
RANGE |
BACKGROUND |
TELEDYNE MODEL |
|
PSA Unit |
||||||
|
H2 purification off gas |
PPM CO |
0-10 ppm |
H2 |
7500Z NDIR Series |
|
|
||||||
Sulfur Recovery Unit (SRU) |
||||||
|
Flue gas to SRU stack incinerator |
Percent O2 & SO2 |
0-5%O2 |
Flue gas |
||
|
||||||
Tail Gas Treating Unit (TGTU) |
||||||
|
SCOT quencher overhead |
Percent H2 |
0-4, 0-8% |
N2 / CO2 / H2S |
||
Recycle gas compressor discharge |
70-100% |
CH4, H2S + trace HC |
||||
Recycle gas to gas scrubber |
Percent H2S |
0-5% |
H2, CH4, H2O |
6000 (UV) |
||
Recycle gas scrubber overhead |
PPM H2S |
0-2000 ppm |
H2, CH4, H2O |
|||
|
||||||
Isomerization Unit |
||||||
|
Recycle gas |
Percent H2 |
50-100% |
C1, C2, C3 + |
||
Process gas / "Burn off only" |
Percent O2 |
0-5% |
N2, CO2 |
|||
|
||||||
Waste Water Treatment Unit (WWTU) |
||||||
|
Setting pond / Drain channel |
Oil |
0-10 ppm |
Rain run-off, etc. |
6600 (UV) |
|
API SINK |
0-100 ppm |
Catch basin |
||||
|
||||||
Carbon Black Unit |
||||||
|
Partial combustion - furnace process |
Percent O2 |
0-5% |
C.B + H.C + CO |
9500 (dirty application) |
|
|
||||||
Methanol / MTBE |
Purge gas to reformer |
Percent H2 |
70-100% |
CH4 / CO2 / CH3OH |
||
Methanol convertor effluent |
CH4 / CO2 / CO / N2 |
|||||
Circulator gas compressor |
||||||
Net gas from knockout pot |
50-100% |
C1, C2, C3, C4 |
||||
Reactor column - purification |
Percent CH3OH |
0-2% |
MTBE |
5020 (NIR) |
||
MTBE in gasoline |
Percent MTBE |
0-20% |
Gasoline |
|||